Login|Register|Forget password|Dashboard Back to Home|Contact|Shopcart
Unverified1st Year

Zhejiang Wangjia Electric Technology Co., Ltd.  

Agriculture & Food

Search
新闻中心
  • 暂无新闻
产品分类
  • 暂无分类
联系方式
  • 联系人:Shengtai Cheng
  • 电话:86-18815122820
站内搜索
 
荣誉资质
  • 暂未上传
友情链接
  • 暂无链接
首页 > Products > Fire Equipment Power Supply Monitor Wjf-800t-2
Fire Equipment Power Supply Monitor Wjf-800t-2
单价 $15.80 / Pieces对比
询价 暂无
浏览 253
发货 Chinazhejiangwenzhou
过期 长期有效
更新 2020-08-04 05:41
 
详细信息
Product Name: Fire Equipment Power Supply Monitor Wjf-800t-2 Model NO.: WJF-800T-2 Receive Frequency: 20-60Hz Alarm Volume (within 1m): ?90dB Transmission Mode: Cable Working Principle: Electro-Acoustic Style Application: Indoor Certification: CCC Working Mode: Active Signal Transmission: Wired Alarm Type: Industry Alarm Transport Package: Package Origin: China Product Description 1, Product overviewThe fire power supply monitor (current and voltage sensor) is developed and produced according to the requirements of gb18284-2011 standard (fire equipment power supply monitoring system). It mainly monitors the current, voltage value, switch value and other parameters of the fire equipment power supply, judges whether the power supply of the fire equipment is normal, guarantees the normal operation of the fire equipment to the greatest extent, and avoids fire and other abnormal conditions Loss of life and property.2, Basic functions1. Real time monitoring function of current value, voltage value and switch value status;2. Audible and visual alarm function;3. Can bus communication function;4. Fire linkage function.3, Technical parameters1. Working power supply AC220V / DC24V optional (normal working state ≤ 0.5W, alarm state ≤ 1W)2. Monitoring alarm: overvoltage, undervoltage, overcurrent, phase loss, power loss, leakage;3. Monitoring voltage: rated value AC220V;7, Wiring instructions:1. One circuit three-phase power supply monitoring wiring diagramWiring Description: upper row terminals: 1, 2, 3, 4, 5 and 6 are connected with three-phase current transformer, 7, 8, 9 and 10 are connected with common three-phase four wire voltage signal, 11, 12, 13 and 14 are connected with leakage input;Lower row terminals: 1, 2 and 3 are connected with working power supply of 220V, 4 and 5 are connected with host can communication h, l, 6 and 7 are empty terminals, 8 and 9 are connected with fire linkage of 24V, 10 are empty terminals, 11 and 12 are connected with alarm output;2. Wiring diagram of two-way three-phase power supply monitoringWiring instructions:Upper row terminals: 1, 2, 3, 4, 5 and 6 are connected with three-phase current transformer, 7, 8, 9 and 10 are connected with common three-phase four wire voltage signal, 11, 12, 13 and 14 are connected with standby three-phase four wire voltage signal input. Lower row terminals: 1, 2 and 3 are connected with working power supply of 220V, 4 and 5 are connected with host can communication h, l, 6 and 7 are empty terminals, 8 and 9 are connected with fire linkage of 24V, 10 are empty terminals, 11 and 12 are connected with alarm output;3. Single phase power supply monitoring wiring diagramWiring instructions:Upper row terminals: 1, 2, 3, 4 air terminals, 5, 6 current signals, 7, 8 air terminals, 9, 10 voltage signals, 11, 12, 13, 14 leakage inputs;Lower row terminals: 1, 2 and 3 are connected with working power supply of 220V, 4 and 5 are connected with host can communication h, l, 6 and 7 are empty terminals, 8 and 9 are connected with fire linkage of 24V, 10 are empty terminals, 11 and 12 are connected with alarm output;8, Outline and installation dimension (unit: mm)1. Overall dimension of guide rail: 110mm * 88mm * 59mm, installation dimension: 35mm standard guide rail;9, Storage and transportationProducts shall not be severely impacted during transportation and unpacking, and shall be transported and stored in accordance with GB / t1546-1995 (technical conditions for packaging and transportation of instruments and meters). The place to be preserved shall be clean, with an ambient temperature of - 40-85 ºC and a relative humidity of not more than 90%. And there is no harmful substance enough to cause corrosion in the air.10, Packing instructions:There shall be fire power monitor (current and voltage sensor), operation instruction and Certificate in the packing box.11, Special reminder: the company's fire power monitor (current and voltage sensor) must be connected correctly when connecting current and voltage signals, and must be connected according to the wiring diagram on the product.12, Contact usThank you for choosing our fire power monitor. Please keep close contact with our dealer or after-sales service department so that we can provide you with more timely and high-quality service!4. Measurement accuracy: class 0.55. Switch output: one passive normally open point, contact capacity AC220V / 3a, dc30v / 3A;6. Communication: can bus communication, no more than 1km7. Baud rate: 9600bps;8. Working environment: relative temperature - 10 ºC - + 70 ºC,Relative humidity ≤ 95%, no condensation9. Executive standard: gb28184-2011 standard.4, Introduction to key indicator1. Operation: when the monitor works normally, this light is on;2. Communication: this light is on when networking with the host;3, Over-current: when the load over-current reaches the set value, the light will be on with alarm sound;4. Over voltage: when the monitoring voltage is higher than the set value, this lamp will be on with alarm sound;5. Undervoltage: when the monitoring voltage is lower than the set value, this light will be on with alarm sound;6. Loss of power: when the monitoring voltage value is 0V, this light will be on with alarm sound;7. Standby power / leakage: when checking the voltage value of standby power supply on the machine, this light will be on. When the monitoring leakage current reaches the set value, this light will be on with an alarm sound (when two-way three-phase power supply monitors, there is no leakage monitoring function) (when one-way three-phase power supply monitors, there is no standby power to check);8. Silencing: when the silencing key is pressed for alarm, the light will be on; and the alarm sound will be eliminated;5, Key function introduction1. Setting: press this key to enter successively for parameter setting;2. "Up" and "down" keys: when viewing various parameters and setting parameters, press this key to turn pages or increase or decrease the parameter value to be adjusted;3. Confirm / mute: after the parameters are changed, press this key to save (press this key to mute during normal operation);4. Shift: press this key to select the cursor when changing parameters;5. Reset: press this key to reset all alarm values in the alarm state and when the fault has been eliminated.6, Parameter setting1. One three-phase (two three-phase) power supply monitoring setting method:Press the "set" key to display "P-00" on the upper digital tube, press the "shift" key to display "0000" on the lower digital tube, press the down key to input the password "9999", press the OK key to return to the "P-00" on the upper digital tube, and enter in sequence:Press the up key to display "P-01" to set the current transformer ratio: the factory setting of our company is 50mA (* *: 50mA), users can select the current transformer ratio according to the current a number of their own switches, for example: the rated current of the switch is 100A, the current transformer must be selected as 100:50ma, the monitoring current of the monitor can be adjusted as 100, and so on;Press the up key to display "P-02" to set the voltage transformation ratio. The factory setting of our company is 500V, and the user does not need to reset;Press the up key to display "P-03" for over-current setting. The factory setting of our company is 120%. When the overload exceeds 120%, the alarm will alarm, and the user does not need to reset;Press the up key to display "P-04" for over-voltage setting. The factory setting of the company is 52%. When the over-voltage exceeds 52%, the alarm will be given, and the user does not need to reset;Press the up key to display "P-05" for undervoltage setting. The factory setting of our company is 36%. When the overpressure is lower than 36%, the alarm will alarm, and the user does not need to reset;Press the up key to display "P-06" for alarm delay setting (0-30s adjustable), and the company's setting is 1s;Press the up key to display "P-07" to set the IP communication address code, which is not required when the host is not connected;Press the up key to display "P-08" to set the leakage alarm value. The factory setting of our company is 500mA; (this function is not available for two-way three-phase power supply monitoring)